| Dokumendiregister | Riigimetsa Majandamise Keskus |
| Viit | 3-1.1/5015 |
| Registreeritud | 11.07.2025 |
| Sünkroonitud | 29.12.2025 |
| Liik | Kiri |
| Funktsioon | 3-1.1 |
| Sari | Metsahalduse / Maakasutuse alane kirjavahetus |
| Toimik | |
| Juurdepääsupiirang | Avalik |
| Juurdepääsupiirang | |
| Adressaat | STROMTEC OÜ |
| Saabumis/saatmisviis | STROMTEC OÜ |
| Vastutaja | Jürgen Kusmin |
| Originaal | Ava uues aknas |
19101:001:0627 Jõeääre
88701:001:0606 Naareti
88703:002:0096 Mängi
88703:002:0143 Koskla
88703:002:0690 Liivranna
88703:002:1070 Lepa
88703:002:1850 Peetri
88703:002:1912 Lepiku
88703:002:2060 Uustalu
88703:002:2061 Laine
88703:002:2142 Naaretimetsa
88703:002:2144 Jõekääru
19101:001:0626 Kukeseene
88701:001:0883 M
ustoja-H aili-Vihula tee L3
88703:002:0097 Sagadi metskond 85
88703:002:0065 Kalda
88703:002:0680 Koemetsa
88703:002:1710 Sagadi metskond 44
88703:002:1800 Juhani
88703:002:2593 Käspri
4.00
3.72
3.89 3.75 3.74
3.78
3.99
3 .9
4 3
.3 9
3 .9
2
3 .7
0 3 .8
4 3
.3 7
3.86 3.86
3.89 3.91 3.99
4.15 4.23
2.91
2.97 2.38
2.47
2.75
2.24
2.72
1.89
2.47
2.61
2.56
2.32 2.45
2.30 2.40
2.54
2.71
2.79 2.71
2.54 1.76
1.38
1.37
1.45 1.32 1
.1 0
0.62
0. 54
1 .2
0 0. 41
0.27
0 .4
7
0.67
0.62
0.42
0.55 1.48
1.24
1.00
0.89
1.37
2.24 2.63
0.96
2.55
2.55
2.56
2.55 -0.08
1 .2
2
-0.06 0.83
1.18
1.53
2.39
1.99 2.06
2. 28
2.29
2.38
1.28 0.66
1.26
2.65
2.29
2.71
2.69
2.82
2.77
3.18
2 .8
6
18.41
18.57
18.27
17.95 18.02
17.82 18.13
18.11
18.02
17.83
18.17
18.41
18.17
18.32
18.04 18.17
18.24 18.12
17.89
18.37
17.68 17.33
17.01 17.19
16.92
17.04
16.82 16.82
16.78 16.65
16.76
16.77
16.42
16.32
16.08
16.19
15.90
15.73
15.49
15.48
15.05
15.44 14.74
15.26 14.46
14.68
14.14
14.02 14.07
14.49
14.62
15.07
15.08 15.12
15.36
15.40 15.56
15.76
15.68
15.91 16.16
16.16 16.39 16.57
16.40
16.56 16.62
17.01 16.82
17.28
17.28
17.92
17.53
18.26 18.00
18.24
17.96 18.16
18.29
18.05
18.31
18.16
17.99
18.01
17.88 17.99
1 7.
75
17.64
18.08
17.91
17.55
18.14
3.91
3.87
4.16
4.23
3.95 3.95
4.16
4.11 4.07
4 .2
8
4 .1
1
4.10 4.19 4.15
4.23
4.86
4.81 4.69
4.94 4.23
3.49
3.51
4.06
4.68 4.68
4.93
5.19
5 .0
6 5.14
4.94
5 .7
6
5.68
6.06 5.74
5.64
5.47
4.90
5.13
4.84 4.84
4.94
4.94 4.94
5.01
5.08
4.97
4.95
5.15
5.04
5.04
5.47 5.42
5.60
5.50
5 .6
2
5.50
5.35
5 .2
0
5.69
5.96
5.65
5.56 5.60
5.59
5.73
5.65
5.57
5.78 6.12
5.66
5.73
5.77 5.68
5.64
5.51
5.59 6.05
5.77
5.91 6.37 6.14
6.09 6.14
6.52
6.18
6.46
6.29
6.45
6.20
6.32
6.24
6.32
6.55
6.49
6.26
6.62
6.37
6.40
6.55
6.41
6.66
6.43
6.60 6.42
6.41
6.67
6.69
6.88 6.61
6.67
7.04 7.48
6.84
6.86
7.22 6.86
6.86 7.15
7.13
6.91
6.84
6.83
7.22 6.92
6.86 7.12
7.21 7.04
6.97
7.14
7.20
7.51
7.46
7.52
7.32
7.37
7.49 7.65
7.84 7.59
7.54 7.81
7.71 7.56
7.73 7.77
7.73
7.62
7.65
7.85
7.91 7.69
7.69
7.74
7.68
7.70
7.86
7.83
8.09
8.08
7.65
7.85
7.89
7.72 7.93
7.75
7.96
8.16
7.84
7.86
7.72 7.82
8.13
7.98
7.98 8.13
8.01
7.96
8.17 8.01
7.99 8.02
7.49
7.86 7.68
7.65
7.69 7.57 7.42
7.70
7.45
7.40 7.62
7.62
7.38
7.41 7.34
7.36
7.30
7 .4
9
7.31
7.39
7.09
7.24 7.38
7.41
7.39
7.26 7.11
7.32
7.32
7.41
7.61 7.32
7.47
7.25
7.32
7.20
7.17
7.17
7.22
7.22
7.20
7.18 7.12
7.08 7.12
7.15
7.17
7.12
7.06 7.06
7.14
7.13
7.06
7.05
7.22 7.06
7.00 7.00
6.80
6.80 6.95
7.14
6.50
6.57
6.50
6.37
6.70
6.42
6.37 6.33
6.36
6.20
6.67 6.24
6.05 6.31
5.96
5.79 5.84
6.06 5.70
5.70
5.88
5.60
5.65 5.50
5.61
5.66
5.50
5.40
5.41
5.55
5.39
5.28
5.22
5.08
5.43
5.02
5.06
4.96 4.95
5.07 5.02
5.08
5.06
5.22
5.20
5.40
2.66
2.94
3.71 4.12
3.52
2.83
3.32
3.22
3.72 3.22
3.94
4.22
4.44 4.63
5.30 5.28
5.19
5 .0
8
4.67 4.79
5.00
4.56
4.64
4.52
4.89
5.12
5.17 5.05
5.14
5.22
5.07
5.00 5.01
4.92 4.86
4.84
6.35
7.85
8.07
8.12
7.89
7.50
7.17
6.53
5.95
5 .3
8
5 .4
7
5.32
5.09
5.13
4.96
4.98
4.99
4.80
4.94
4.90
5.16
5.52
5.36
6.02
6.65
6.75
6.90
7.13 7.41 7.45
7.60
7 .6
7
7. 96
7. 94
7.82
7 .6
3
7.60 7 .6
2
7.38
7.50
7 .5
2
7 .6
3
7.35
7 .9
2
7 .8
6
8.22
8 .0
9 8
.4 1 8.33
8.83
8.93 8.64
8.95
8 .6
8
9.02 9.39
9.39
9.69
9.31
9.49 9.87
9.91
9.60
9.91
9.62
9.56
9.61
9.63
9.54
9.72 9.70
9.66
9.67
9.66
9.59 9.68
9.59
9.67 9.74
9.71
9.72
9.70
9.64
9.62
9.57
9.51 9.53 9.47
9.71
9.57 9.74
9.64
9.92
9.79
9 .6
8
9 .7
5
9.81
9.76 9.84
9.74
9.89 9.85
9.97
10.10
10.47 10.15
10.11 10.33
10.65
10.48
1 0.
47
10.33
10.77 10.75 10.35
10.35
1 0.
64
10.92 1 0.
76
11.08
1 1.
00 1
1. 04
11.48
11.47
1 1.
44 1
1. 44 11.67
12.09
1 1.
87
12.06 1 1.
91
12.23
1 2.
26 1
2. 19
12.62
1 2.
45
12.58
12.88
12.89 1 2.
75
1 2.
81
1 3.
02
1 3.
01
12.95
1 3.
80
13.39 13.22
13.01
13.09
1 3.
05
1 3.
06
1 3.
02
1 3.
03
13.06
1 2.
97
13.04
13.10
13.09
13.11 13.19
13.16
13.21
13.35
13.40 13.66
13.94
13.56 13.98
13.79
13.92
22.19
22.09
21.85 21.90
21.49
21.55
21.73
21.88
22.17 21.88
22.02 22.33
22.37 22.48
22.73
22.29
21.07
21.46 21.68
22.04
21.87
22.09
21.98
21.74
22.01
22.06 21.88
21.50
21.50
21.34 21.11
21.19
21.60
19.12
18.91
18.84
18.57
18.28
18.35
18.25
18.46 18.57
18.65
18.69
18.95
19.05
18.95
19.30
19.09
19.10 19.24
19.14
18.96 19.22
18.79 19.16
19.13
18.68
19.00
19.28
19.40
19.33
19.33
19.81
20.74
19.98
19.98
20.52 20.54 20.98
20.93
20.71
20.71
20.64
21.28
21.08
20.95
20.83 20.87
20.48
20.79
20.83
AJ
rahn
7 .9
3
1. 23
1.57
1 .1
5
2.01
1.91
3.73
3.64
4.42
1.12
2.37
lõkkekoht
2.76
2.49 2.76
2.83
info
silt
rahn
Ø700 Bet 2.83-3.16
5.55
Ø400 Bet 3.64-4.46
5.55
2 .6
5
2 .9
0
sipelgapesa
sipelgapesa
sipelgapesa
sipelgapesa
5.25
5.38
5.41
AJ
5.40
M ustoja oja
M us
to ja
o ja
bet sild
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
pinn
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr pinn
pinn
Kr
pin n
Kr
Kr
Kr
pa ek
ki ll
Kr
Kr
pinn
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
pinn
wc 3.83
3.81
3.99 3.83
Kr
Kr Kr
Kr
X = 6606900
Y = 621150
X = 6606950
Y = 621100
X = 6606900
Y = 621800
X = 6606800
Y = 622000
X = 6606900
Y = 622150
X = 6606850
Y = 622300
X = 6606950
Y = 622400
X = 6606950
Y = 622550
X = 6607000
Y = 622700
X = 6606900
Y = 622750
X = 6607050
Y = 622850
X = 6606950
Y = 622900
X = 6607000
Y = 623000
X = 6606800
Y = 623050
X = 6606700
Y = 623000
X = 6606650
Y = 623100
X = 6606550
Y = 623050
X = 6606350
Y = 623050
X = 6606200
Y = 623200
X = 6606100
Y = 623150
1W2
1W2
1W2
1W2
W2
1W2
1W 2
1W2 1W2
1W2 1W
1W2
1W2
1W2
1W2 1W2
1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W 2
1W2
1W2
1W2
1W
1W2
1W2 1W2
1W2 1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
88703:001:0005 Jaanirahva
88703:001:0863 Toomavälja
88703:001:3010
17181 Võsu-Vergi-Söeaugu tee
88703:001:0057 Mäe kõrts
88701:001:0644 Sagadi metskond 296
19101:001:0840 Paarma
88703:001:0151 Paarma-Rommani
88703:002:0178 Sagadi metskond 119
88703:002:1960 Rannala
88703:002:1710 Sagadi metskond 44
88703:002:0139 Sinilinnu
88703:002:0144
Külaotsa tee
88703:002:2420 Kagamanni
OBJEKT
AADRESS
TÖÖ NR
TÖÖ KOOD
KOOSTAS
1:500 1 / 6
FAIL
13724G
13724G Mustoja geoalus
Geodeetiline alusplaan
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp
Lääne-Viru maakond Haljala vald Mustoja küla
J. Rump
IP7497
KONTROLLIS
Koordinaadid L-EST97 süsteemis, kõrgused EH2000 süsteemis Katastriüksuste piirid: väljavõte Maa- ja Ruumiametist 19.06.2025. Kihil "PIIR" esitatud piirjoonte asukohad on informatiivsed.
Märkused:
MÕÕDISTATUD 17.06.25
M. Sepp TEL003987 EEG000316 EEP004848 [email protected], rg-kood 12592543
Lossi 33 Põltsamaa linn Jõgevamaa 48104
MÕÕTKAVA LEHT JOONIS
X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X X
X X X
X
X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X X
X
X
88703:002:1690 Sagadi metskond 40
88703:002:1690 Sagadi metskond 40
88703:002:1690 Sagadi metskond 40
88703:001:0151 Paarma-Rommani
88703:002:1690 Sagadi metskond 40
88703:002:1960 Rannala
Joonis 02
Joonis 01
Joonis 03 Joonis 02
Joonis 04
Joonis 03
Joonis 05
Joonis 04
Joonis 07
Joonis 06
Joonis 08
Joonis 07
Joonis 09 Joonis 08
Joonis 10 Joonis 09
Joonis 05
Joonis 06
N
N
N
N N
N
N
N
N
N
N
88703:002:2144 Jõekääru
88703:002:2142 Naaretimetsa
88703:002:1710 Sagadi metskond 44
88703:002:1710 Sagadi metskond 44
88703:002:2420 Kagamanni
88703:002:1710 Sagadi metskond 44
19101:001:0840 Paarma
88703:002:0012 Kraavi
88703:002:0139 Sinilinnu
88703:002:0140 Kajaka
3 x AS-25 Alajaam AJ Altja
Demonteerida puit mast koos mastivõimsuslülitiga Mustoja LP
Demonteerida puit mast koos lahklülitiga Mustoja LP
3 x PAS-50
Viia tööst välja keskpinge maakaabel nr 538 AABL 3x50 alates LL Mustoja LP kuni M150H7
Demonteerida raudbetoon mast koos raudbetoon toega Demonteerida raudbetoon mast
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida puit mast koos lahklülitiga Mustoja 2 LP
Demonteerida keskpinge õhuliin 3 x PAS-50, L(trass)=5m alates mast M150H26 kuni mast M150H27
Demonteerida madalpinge õhuliin AMKA 3x50+70, L(trass)=3m alates AJ Mustoja F3 kuni mast M1
Demonteerida madalpinge õhuliin AMKA 3x50+70, L(trass)=3m alates AJ Mustoja F2 kuni mast M1
Demonteerida madalpinge õhuliin AMKA 3x70+95, L(trass)=3m alates AJ Mustoja F1 kuni mast M1
Keskpinge maakaabel nr 556 AHXAMK-W 3x70+35 võtta masti küljest lahti ning pikendada alajaama AJ17045
Raadada kaevetööde ulatuses mets/võsa ca 130m²
Alajaam AJ Mustoja II
Ettevaatust, elektritrassid!
Taastada kruuskatend kaevetööde ulatuses ca 13m²
Taastada haljastus kaevetööde ulatuses ca 1253m²
Taastada kruuskatend kaevetööde ulatuses ca 167m²
Raadada kaevetööde ulatuses mets/võsa ca 28m²
Raadada kaevetööde ulatuses mets/võsa ca 83m²
Raadada kaevetööde ulatuses mets/võsa ca 4m²
Raadada kaevetööde ulatuses mets/võsa ca 1m²
Taastada kruuskatend kaevetööde ulatuses ca 10m²
Taastada kruuskatend kaevetööde ulatuses ca 49m²
Taastada kruuskatend kaevetööde ulatuses ca 98m²
Taastada kruuskatend kaevetööde ulatuses ca 47m² Taastada kruuskatend kaevetööde ulatuses ca 48m²
Taastada kruuskatend kaevetööde ulatuses ca 14m²
Taastada kruuskatend kaevetööde ulatuses ca 20m²
Taastada kruuskatend kaevetööde ulatuses ca 11m²
Taastada kruuskatend kaevetööde ulatuses ca 39m²
Taastada kruuskatend kaevetööde ulatuses ca 30m²
Taastada kruuskatend kaevetööde ulatuses ca 16m² Taastada kruuskatend kaevetööde ulatuses ca 10m²
Taastada kruuskatend kaevetööde ulatuses ca 13m²
Taastada kruuskatend kaevetööde ulatuses ca 21m²
Taastada kruuskatend kaevetööde ulatuses ca 9m²
Taastada kruuskatend kaevetööde ulatuses ca 447m²
Raadada kaevetööde ulatuses mets/võsa ca 4m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 24m²
Raadada kaevetööde ulatuses mets/võsa ca 55m²
Raadada kaevetööde ulatuses mets/võsa ca 22m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 32m²
Raadada kaevetööde ulatuses mets/võsa ca 23m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 16m²
Raadada kaevetööde ulatuses mets/võsa ca 5m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 1m²
Raadada kaevetööde ulatuses mets/võsa ca 14m²
Raadada kaevetööde ulatuses mets/võsa ca 13m²
Raadada kaevetööde ulatuses mets/võsa ca 6m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 1m²
Alajaam AJ Metsakalju
Taastada haljastus kaevetööde ulatuses ca 9m²
Taastada haljastus kaevetööde ulatuses ca 123m²
Taastada haljastus kaevetööde ulatuses ca 61m²
Taastada haljastus kaevetööde ulatuses ca 47m²
Taastada haljastus kaevetööde ulatuses ca 71m²
Taastada haljastus kaevetööde ulatuses ca 115m²
Taastada haljastus kaevetööde ulatuses ca 305m²
Taastada haljastus kaevetööde ulatuses ca 1m²
Taastada haljastus kaevetööde ulatuses ca 836m²
Taastada haljastus kaevetööde ulatuses ca 7m²
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ristumisel kraaviga paigaldada kaabel kraavi põhjast minimaalselt 1,0m sügavamale
Ristumine ojaga rajada kinnise läbindamise meetodil kaitsetorus Ø160; 1250N; L(trass/toru)=40/42m; sügavusel min 1,0m oja põhjast
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
Demonteerida alajaam AJ Mustoja koos radubetoon jalanditega
Kaabli nr 556 AHXAMK-W 3x70+35Cu uus trassikoridor, L(trass)=8m. Vajadusel pikendada kaablit, et ühendada projekteeritud alajaama AJ17045
Projekteeritud maakaabel MPL436139 AJ17045 F5 - õhuliini mast M1
AXPK 4G120; L(trass/kaabel)=3/16m kaitsetorus Ø110; 450N; L(trass/toru)=3/5m; sügavusel 0,7m
Projekteeritud maakaabel MPL436140 AJ17045 F3 - õhuliini mast M1
AXPK 4G120; L(trass/kaabel)=2/15m Projekteeritud maakaabel MPL436141
AJ17045 F1 - õhuliini mast M1 AXPK 4G120; L(trass/kaabel)=2/15m
kaitsetorus 2xØ110; 450N; L(trass/toru)=2/4m; sügavusel 0,7m
Projekteeritud alajaam AJ17045
Taastada haljastus kaevetööde ulatuses ca 68m²
88701:001:0883 M
ustoja-H aili-Vihula tee L3
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 00 Mõõtkava: M1:5000/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
Joonis 0
Jo n 09
Joonis 08 Joonis
Joonis 6Joo is 01
Joonis 02 Joonis 03 Joonis 04
Joonis 0 m
in . 2
5 cm ra
ja tis
e te
ge lik
pa ig
al du
ss üg
av us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)
OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
88703:001:0005 Jaanirahva
88703:001:0863 Toomavälja
88703:001:3010
17181 Võsu-Vergi-Söeaugu tee
88703:001:0057 Mäe kõrts
88701:001:0644 Sagadi metskond 296
19101:001:0840 Paarma
88703:001:0151 Paarma-Rommani
X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X X
X X X
X
X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X X
X
X
88703:002:1690 Sagadi metskond 40
Joonis 02
N
3 x AS-25 Alajaam AJ Altja
Demonteerida puit mast koos mastivõimsuslülitiga Mustoja LP
Demonteerida puit mast koos lahklülitiga Mustoja LP
3 x PAS-50
Viia tööst välja keskpinge maakaabel nr 538 AABL 3x50 alates LL Mustoja LP kuni M150H7
Demonteerida raudbetoon mast koos raudbetoon toega Demonteerida raudbetoon mast
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 01 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X X
X X X
X
X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
88703:002:1690 Sagadi metskond 40
88703:001:0151 Paarma-Rommani
Joonis 01
Joonis 03
N 19101:001:0840 Paarma
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 02 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X X
X X X
X
X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
88703:002:1690 Sagadi metskond 40
Joonis 02 Joonis 04
N
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 03 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
88703:002:0178 Sagadi metskond 119
88703:002:1960 Rannala
X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X X
X X X
X
X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
88703:002:1690 Sagadi metskond 40
Joonis 03
Joonis 05
N
Demonteerida raudbetoon mast Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 04 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
88703:002:0690 Liivranna
88703:002:1070 Lepa
88703:002:2060 Uustalu
88703:002:2061 Laine
88703:002:0680 Koemetsa
4.00
3.72
3.89 3.75 3.74
3.78
3.99
3 .9
4 3
.3 9
3 .9
2
3 .7
0 3 .8
4 3
.3 7
3.86 3.86
3.89 3.91 3.99
4.15 4.23
3.91
3.87
4.16
4.23
3.95 3.95
4.16
4.11 4.07
4 .2
8
4 .1
1
4.10 4.19 4.15
4.23
wc 3.83
3.81
3.99 3.83
Kr
Kr Kr
Kr
X = 6606900
Y = 621150
X = 6606950
Y = 621100
X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X X
X X X
X
X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
88703:002:1960 Rannala
Joonis 04
Joonis 06
Trafo
MP-seade
KP-seade
N
88703:002:0012 Kraavi
1W 2
2W 1
1W1
Demonteerida raudbetoon mast
Demonteerida raudbetoon mast
Demonteerida keskpinge õhuliini 3 x AS-25, L(trass)=1781m alates mast M150H7 kuni AJ Mustoja
Demonteerida raudbetoon mast koos raudbetoon toega
Demonteerida puit mast koos lahklülitiga Mustoja 2 LP
Demonteerida keskpinge õhuliin 3 x PAS-50, L(trass)=5m alates mast M150H26 kuni mast M150H27
Demonteerida madalpinge õhuliin AMKA 3x50+70, L(trass)=3m alates AJ Mustoja F3 kuni mast M1
Demonteerida madalpinge õhuliin AMKA 3x50+70, L(trass)=3m alates AJ Mustoja F2 kuni mast M1
Demonteerida madalpinge õhuliin AMKA 3x70+95, L(trass)=3m alates AJ Mustoja F1 kuni mast M1
Keskpinge maakaabel nr 556 AHXAMK-W 3x70+35 võtta masti küljest lahti ning pikendada alajaama AJ17045
Demonteerida alajaam AJ Mustoja koos radubetoon jalanditega
Kaabli nr 556 AHXAMK-W 3x70+35Cu uus trassikoridor, L(trass)=8m. Vajadusel pikendada kaablit, et ühendada projekteeritud alajaama AJ17045
Projekteeritud maakaabel MPL436139 AJ17045 F5 - õhuliini mast M1
AXPK 4G120; L(trass/kaabel)=3/16m kaitsetorus Ø110; 450N; L(trass/toru)=3/5m; sügavusel 0,7m
Projekteeritud maakaabel MPL436140 AJ17045 F3 - õhuliini mast M1
AXPK 4G120; L(trass/kaabel)=2/15m Projekteeritud maakaabel MPL436141
AJ17045 F1 - õhuliini mast M1 AXPK 4G120; L(trass/kaabel)=2/15m
kaitsetorus 2xØ110; 450N; L(trass/toru)=2/4m; sügavusel 0,7m
Projekteeritud alajaam AJ17045
Taastada haljastus kaevetööde ulatuses ca 68m²
M 1:50 1.40
0. 70
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 või Ø110 mm) 450N (Stromtec OÜ, töö nr 25-15)
hoiatuslint
≥0.30
0.600.60
≥0.30
Kasvupinnas ja muru külv h= 10 cm Kaeviku tagasitäide välja kaevatud materjaliga, kt=0,92 h= 40 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥60 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥60 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥60 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
≥0.10≥0.10
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 05 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
m in
. 2 5
cm ra ja
tis e
te ge
lik pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
88703:002:0096 Mängi
88703:002:0143 Koskla
88703:002:1850 Peetri
88703:002:1912 Lepiku
88703:002:0097 Sagadi metskond 85
88703:002:1800 Juhani
7.49
7.86
7.57 7.42
7.70
7.45
7.40 7.62
7.62
7.38
7.41 7.34
7.36
7.30
7 .4
9
7.31
7.39
7.09
7.24 7.38
7.41
7.39
7.26 7.11
7.32
7.32
7.41
7.61 7.32
7.47
7.25
7.32
7.20
7.17
7.17
7.22
7.22
7.20
7.18 7.12
7.08 7.12
7.15
7.17
7.12
7.06 7.06
7.14
7.13
7.06
7.05
7.22 7.06
7.00 7.00
6.80
6.80 6.95
7.14
6.50
6.57
6.50
6.37
6.70
6.42
6.37 6.33
6.36
6.20
6.67 6.24
6.05 6.31
5.96
5.79 5.84
6.06 5.70
5.70
5.88
5.60
5.65 5.50
5.61
5.66
5.50
5.40
5.41
5.55
5.39
5.28
5.22
5.08
5.43
5.02
5.06
4.96 4.95
5.07 5.02
5.08
5.06
5.22
5.20
5.40
sipelgapesa
sipelgapesa
sipelgapesa
5.25
5.38
5.41
AJ
5.40
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
pinn
Kr
X = 6606800
Y = 622000
X = 6606900
Y = 622150
1W2
1W2
1W2
1W2
W2
1W2
1W 2
1W2 1W2
1W2 1W
1W2
1W2
1W2
1W2 1W2
1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W 2
1W2
1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
88703:002:1710 Sagadi metskond 44
88703:002:0139 Sinilinnu
88703:002:0144
Külaotsa tee
Joonis 07
Joonis 05
N
88703:002:1710 Sagadi metskond 44
Raadada kaevetööde ulatuses mets/võsa ca 130m²
Alajaam AJ Mustoja II
Ettevaatust, elektritrassid!
Taastada kruuskatend kaevetööde ulatuses ca 13m²
Taastada haljastus kaevetööde ulatuses ca 1253m²
Taastada kruuskatend kaevetööde ulatuses ca 167m²
Raadada kaevetööde ulatuses mets/võsa ca 28m²
Raadada kaevetööde ulatuses mets/võsa ca 83m²
Raadada kaevetööde ulatuses mets/võsa ca 4m²
Raadada kaevetööde ulatuses mets/võsa ca 1m²
Taastada kruuskatend kaevetööde ulatuses ca 10m² Projekteeritud maakaabel KPL414478
AJ Mustaoja II - AJ Metsakalju AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m
kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
M 1:50 3.00
1. 00
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 mm) 750N (Stromtec OÜ, töö nr 25-15)
0.300.30 0.30 0.30
hoiatuslint min 0.30
min 0.30
≥0.30
0.600.60
≥0.30
Purustatud kruus fr. 0.063 ...32 h= 10 cm Paekillustikust alus fr.32/63, kiilutud E≥170 MPa h= 25 cm Dreenkiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, kt=0,98
h= 20 cm
Tee mulle keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, kt=0,98
h= 25 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥65 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥65 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥65 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
M 1:50 1.40
0. 70
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 või Ø110 mm) 450N (Stromtec OÜ, töö nr 25-15)
hoiatuslint
≥0.30
0.600.60
≥0.30
Kasvupinnas ja muru külv h= 10 cm Kaeviku tagasitäide välja kaevatud materjaliga, kt=0,92 h= 40 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥60 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥60 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥60 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
≥0.10≥0.10
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 06 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis
tegutsemise eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või
raadamisjäätmeid, jääd, lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
m in
. 2 5
cm ra ja
tis e
te ge
lik pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)
OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
88703:002:1710 Sagadi metskond 44
6.14
6.09 6.14
6.52
6.18
6.46
6.29
6.45
6.20
6.32
6.24
6.32
6.55
6.49
6.26
6.62
6.37
6.40
6.55
6.41
6.66
6.43
6.60 6.42
6.41
6.67
6.69
6.88 6.61
6.67
7.04 7.48
6.84
6.86
7.22 6.86
6.86 7.15
7.13
6.91
6.84
6.83
7.22 6.92
6.86 7.12
7.21 7.04
6.97
7.14
7.20
7.51
7.46
7.52
7.32
7.37
7.49 7.65
7.84 7.59
7.54 7.81
7.71 7.56
7.73 7.77
7.73
7.62
7.65
7.85
7.91 7.69
7.69
7.74
7.68
7.70
7.86
7.83
8.09
8.08
7.65
7.85
7.89
7.72 7.93
7.75
7.96
8.16
7.84
7.86
7.72 7.82
8.13
7.98
7.98 8.13
8.01
7.96
8.17 8.01
7.99 8.02
7.86 7.68
7.65
7.69
sipelgapesa
Kr
Kr
Kr
Kr
Kr
X = 6606850
Y = 622300
X = 6606950
Y = 622400
X = 6606950
Y = 622550
1W2
1W2
1W2
1W2
1W2
1W2
1W 2
1W2 1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W 2
1W2
1W2
1W2
1W
1W2
1W2 1W2
1W2 1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
Joonis 06
Joonis 08
N
88703:002:0139 Sinilinnu
88703:002:0140 Kajaka
Taastada kruuskatend kaevetööde ulatuses ca 49m²
Taastada kruuskatend kaevetööde ulatuses ca 98m²
Taastada kruuskatend kaevetööde ulatuses ca 47m² Taastada kruuskatend kaevetööde ulatuses ca 48m²
Raadada kaevetööde ulatuses mets/võsa ca 4m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 24m²
Raadada kaevetööde ulatuses mets/võsa ca 55m²
Raadada kaevetööde ulatuses mets/võsa ca 22m²
Raadada kaevetööde ulatuses mets/võsa ca 32m²
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
M 1:50 3.00
1. 00
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 mm) 750N (Stromtec OÜ, töö nr 25-15)
0.300.30 0.30 0.30
hoiatuslint min 0.30
min 0.30
≥0.30
0.600.60
≥0.30
Purustatud kruus fr. 0.063 ...32 h= 10 cm Paekillustikust alus fr.32/63, kiilutud E≥170 MPa h= 25 cm Dreenkiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, kt=0,98
h= 20 cm
Tee mulle keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, kt=0,98
h= 25 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥65 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥65 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥65 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
M 1:50 1.40
0. 70
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 või Ø110 mm) 450N (Stromtec OÜ, töö nr 25-15)
hoiatuslint
≥0.30
0.600.60
≥0.30
Kasvupinnas ja muru külv h= 10 cm Kaeviku tagasitäide välja kaevatud materjaliga, kt=0,92 h= 40 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥60 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥60 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥60 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
≥0.10≥0.10
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 07 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
m in
. 2 5
cm ra ja
tis e
te ge
lik pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)
OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
88703:002:2593 Käspri
2.91
2.97 2.38
2.47
2.75
2.24
2.72
1.89
2.47
2.61
2.56
2.32 2.45
2.30 2.40
2.54
2.71
2.79 2.71
2.54 1.76
1.38
1.37
1.45 1.32 1
.1 0
0.62
0. 54
1 .2
0 0. 41
0.27
0 .4
7
0.67
0.62
0.42
0.55 1.48
1.24
1.00
0.89
1.37
2.24 2.63
0.96
2.55
2.55
2.56
2.55 -0.08
1 .2
2
-0.06 0.83
1.18
1.53
2.39
1.99 2.06
2. 28
2.29
2.38
1.28 0.66
1.26
2.65
2.29
2.71
2.69
2.82
2.77
3.18
2 .8
6
4.86
4.81 4.69
4.94 4.23
3.49
3.51
4.06
4.68 4.68
4.93
5.19
5 .0
6 5.14
4.94
5 .7
6
5.68
6.06 5.74
5.64
5.47
4.90
5.13
4.84 4.84
4.94
4.94 4.94
5.01
5.08
4.97
4.95
5.15
5.04
5.04
5.47 5.42
5.60
5.50
5 .6
2
5.50
5.35
5 .2
0
5.69
5.96
5.65
5.56 5.60
5.59
5.73
5.65
5.57
5.78 6.12
5.66
5.73
5.77 5.68
5.64
5.51
5.59 6.05
5.77
5.91 6.37 6.14
6.09
2.66
2.94
3.71 4.12
3.52
2.83
3.32
3.22
3.72 3.22
3.94
4.22
4.44 4.63
5.30 5.28
5.19
5 .0
8
4.67 4.79 5.00
4.56
4.64
4.52
4.89
5.12
5.17 5.05
5.14
5.22
5.07
5.00 5.01
4.92 4.86
4.84
6.35
7.85
8.07
8.12
7.89
7.50
7.17
6.53
5.95
5 .3
8
5 .4
7
5.32
5.09
5.13
4.96
4.98
4.99
4.80
4.94
4.90
5.16
5.52
5.36
6.02
6.65
6.75
6.90
7.13 7.41 7.45
7.60
7 .6
7
7. 96
7. 94
7.82
7 .6
3
7.60 7 .6
2
7.38
7.50
7 .5
2
7 .6
3
7.35
7 .9
2
7 .8
6
8.22
8 .0
9 8
.4 1 8.33
8.83
8.93 8.64
8.95
8 .6
8
9.02 9.39
9.39
9.69
9.31
9.49 9.87
9.91
9.60
9.91
9.62
7 .9
3
1. 23
1.57
1 .1
5
2.01
1.91
3.73
3.64
4.42
1.12
2.37
lõkkekoht
2.76
2.49 2.76
2.83
info
silt
Ø700 Bet 2.83-3.16
5.55
Ø400 Bet 3.64-4.46
5.55
2 .6
5
2 .9
0
M ustoja oja
M us
to ja
o ja
bet sild
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr Kr
Kr
Kr
Kr
Kr
Kr
X = 6607000
Y = 622700
X = 6606900
Y = 622750
X = 6607050
Y = 622850
X = 6606950
Y = 622900
X = 6607000
Y = 623000
1W2
1W2
1W2
1W2
1W2
1W2
1W 2
1W2 1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W 2
1W2
1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
Joonis 07
Joonis 09 Joonis 08
N
88703:002:1710 Sagadi metskond 44
88703:002:2420 Kagamanni
Taastada kruuskatend kaevetööde ulatuses ca 14m²
Taastada kruuskatend kaevetööde ulatuses ca 20m²
Taastada kruuskatend kaevetööde ulatuses ca 11m²
Taastada kruuskatend kaevetööde ulatuses ca 39m²
Taastada kruuskatend kaevetööde ulatuses ca 30m²
Taastada kruuskatend kaevetööde ulatuses ca 16m² Taastada kruuskatend kaevetööde ulatuses ca 10m²
Taastada kruuskatend kaevetööde ulatuses ca 13m²
Taastada kruuskatend kaevetööde ulatuses ca 21m²
Taastada kruuskatend kaevetööde ulatuses ca 9m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 23m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 16m²
Raadada kaevetööde ulatuses mets/võsa ca 5m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 1m²
Raadada kaevetööde ulatuses mets/võsa ca 14m²
Raadada kaevetööde ulatuses mets/võsa ca 13m²
Taastada haljastus kaevetööde ulatuses ca 9m²
Taastada haljastus kaevetööde ulatuses ca 123m²
Taastada haljastus kaevetööde ulatuses ca 61m²
Taastada haljastus kaevetööde ulatuses ca 47m²
Taastada haljastus kaevetööde ulatuses ca 71m²
Taastada haljastus kaevetööde ulatuses ca 115m²
Taastada haljastus kaevetööde ulatuses ca 305m²
Ristumisel kraaviga paigaldada kaabel kraavi põhjast minimaalselt 1,0m sügavamale
Ristumine ojaga rajada kinnise läbindamise meetodil kaitsetorus Ø160; 1250N; L(trass/toru)=40/42m; sügavusel min 1,0m oja põhjast
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
M 1:50 3.00
1. 00
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 mm) 750N (Stromtec OÜ, töö nr 25-15)
0.300.30 0.30 0.30
hoiatuslint min 0.30
min 0.30
≥0.30
0.600.60
≥0.30
Purustatud kruus fr. 0.063 ...32 h= 10 cm Paekillustikust alus fr.32/63, kiilutud E≥170 MPa h= 25 cm Dreenkiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, kt=0,98
h= 20 cm
Tee mulle keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, kt=0,98
h= 25 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥65 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥65 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥65 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
M 1:50 1.40
0. 70
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 või Ø110 mm) 450N (Stromtec OÜ, töö nr 25-15)
hoiatuslint
≥0.30
0.600.60
≥0.30
Kasvupinnas ja muru külv h= 10 cm Kaeviku tagasitäide välja kaevatud materjaliga, kt=0,92 h= 40 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥60 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥60 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥60 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
≥0.10≥0.10
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 08 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste kaitsevööndis tegutsemise
eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu- või raadamisjäätmeid, jääd,
lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
m in
. 2 5
cm ra ja
tis e
te ge
lik pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)
OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
88703:002:2144 Jõekääru
16.32
16.08
16.19
15.90
15.73
15.49
15.48
15.05
15.44 14.74
15.26 14.46
14.68
14.14
14.02 14.07
14.49
14.62
15.07
15.08 15.12
15.36
15.40 15.56
15.76
15.68
15.91 16.16
16.16 16.39
9.49 9.87
9.91
9.60
9.91
9.62
9.56
9.61
9.63
9.54
9.72 9.70
9.66
9.67
9.66
9.59 9.68
9.59
9.67 9.74
9.71
9.72
9.70
9.64
9.62
9.57
9.51 9.53 9.47
9.71
9.57 9.74
9.64
9.92
9.79
9 .6
8
9 .7
5
9.81
9.76 9.84
9.74
9.89 9.85
9.97
10.10
10.47 10.15
10.11 10.33
10.65
10.48
1 0.
47
10.33
10.77 10.75 10.35
10.35
1 0.
64
10.92 1 0.
76
11.08
1 1.
00 1
1. 04
11.48
11.47
1 1.
44 1
1. 44 11.67
12.09
1 1.
87
12.06 1 1.
91
12.23
1 2.
26 1
2. 19
12.62
1 2.
45
12.58
12.88
12.89 1 2.
75
1 2.
81
1 3.
02
1 3.
01
12.95
1 3.
80
13.39 13.22
13.01
13.09
1 3.
05
1 3.
06
1 3.
02
1 3.
03
13.06
1 2.
97
13.04
13.10
13.09
13.11 13.19
13.16
13.21
13.35
13.40 13.66
13.94
13.56 13.98
13.79
13.92
Kr
Kr pinn
pinn
Kr
pin n
Kr
Kr
Kr
pa ek
ki ll
Kr
Kr
pinn
Kr
Kr
X = 6606800
Y = 623050
X = 6606700
Y = 623000
X = 6606650
Y = 623100
X = 6606550
Y = 623050
1W2
1W2
1W2
1W2
1W2
1W2
1W 2
1W2 1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W 2
1W2
1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
88703:002:2420 Kagamanni
Joonis 08
Joonis 10
N
88703:002:2142 Naaretimetsa
88703:002:1710 Sagadi metskond 44
88703:002:2420 Kagamanni
Taastada kruuskatend kaevetööde ulatuses ca 9m²
Raadada kaevetööde ulatuses mets/võsa ca 13m²
Raadada kaevetööde ulatuses mets/võsa ca 6m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Raadada kaevetööde ulatuses mets/võsa ca 2m²
Taastada haljastus kaevetööde ulatuses ca 1m²
Taastada haljastus kaevetööde ulatuses ca 836m²
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
88701:001:0883 M
ustoja-H aili-Vihula tee L3
M 1:50 3.00
1. 00
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 mm) 750N (Stromtec OÜ, töö nr 25-15)
0.300.30 0.30 0.30
hoiatuslint min 0.30
min 0.30
≥0.30
0.600.60
≥0.30
Purustatud kruus fr. 0.063 ...32 h= 10 cm Paekillustikust alus fr.32/63, kiilutud E≥170 MPa h= 25 cm Dreenkiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, kt=0,98
h= 20 cm
Tee mulle keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, kt=0,98
h= 25 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥65 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥65 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥65 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
M 1:50 1.40
0. 70
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 või Ø110 mm) 450N (Stromtec OÜ, töö nr 25-15)
hoiatuslint
≥0.30
0.600.60
≥0.30
Kasvupinnas ja muru külv h= 10 cm Kaeviku tagasitäide välja kaevatud materjaliga, kt=0,92 h= 40 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥60 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥60 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥60 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
≥0.10≥0.10
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 09 Mõõtkava: M1:500/A1
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste
kaitsevööndis tegutsemise eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu-
või raadamisjäätmeid, jääd, lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
m in
. 2 5
cm ra ja
tis e
te ge
lik pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
19101:001:0627 Jõeääre
88701:001:0606 Naareti
88703:002:2142 Naaretimetsa
19101:001:0626 Kukeseene
88701:001:0883 M
ustoja-H aili-Vihula tee L3
88703:002:0065 Kalda
18.41
18.57
18.27
17.95 18.02
17.82 18.13
18.11
18.02
17.83
18.17
18.41
18.17
18.32
18.04 18.17
18.24 18.12
17.89
18.37
17.68 17.33
17.01 17.19
16.92
17.04
16.82 16.82
16.78 16.65
16.76
16.77
16.42
16.32 16.16 16.39 16.57
16.40
16.56 16.62
17.01 16.82
17.28
17.28
17.92
17.53
18.26 18.00
18.24
17.96 18.16
18.29
18.05
18.31
18.16
17.99
18.01
17.88 17.99
1 7.
75
17.64
18.08
17.91
17.55
18.14
22.19
22.09
21.85 21.90
21.49
21.55
21.73
21.88
22.17 21.88
22.02 22.33
22.37 22.48
22.73
22.29
21.07
21.46 21.68
22.04
21.87
22.09
21.98
21.74
22.01
22.06 21.88
21.50
21.50
21.34 21.11
21.19
21.60
19.12
18.91
18.84 18.57
18.28
18.35
18.25
18.46 18.57
18.65
18.69
18.95
19.05
18.95
19.30
19.09
19.10 19.24
19.14
18.96 19.22
18.79 19.16
19.13
18.68
19.00
19.28
19.40
19.33
19.33
19.81
20.74
19.98
19.98
20.52 20.54 20.98
20.93
20.71
20.71
20.64
21.28
21.08
20.95
20.83 20.87
20.48
20.79
20.83
AJ
rahn
rahn
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
Kr
pinn
X = 6606350
Y = 623050
X = 6606200
Y = 623200
X = 6606100
Y = 623150
1W2
1W2
1W2
1W2
1W2
1W2
1W 2
1W2 1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W 2
1W2
1W2
1W2
1W2
1W2
1W2 1W2
1W2 1W2 1W2
1W2 1W2 1W2 1W2 1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W2
1W2 1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W 2
1W2
1W2
1W2
1W 2
1W 2
1W 2
1W 2
1W 2
Joonis 09
N
88703:002:2144 Jõekääru
Taastada kruuskatend kaevetööde ulatuses ca 447m²
Raadada kaevetööde ulatuses mets/võsa ca 1m²
Alajaam AJ Metsakalju
Taastada haljastus kaevetööde ulatuses ca 7m²
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Ettevaatust, elektritrass!
Projekteeritud maakaabel KPL414478 AJ Mustaoja II - AJ Metsakalju
AHXAMK-W 3x120+35Cu; L(trass/kaabel)=2236/2250m kaitsetorus Ø160; 750N; L(trass/toru)=2196/2205m; sügavusel min 1,0m
M 1:50 3.00
1. 00
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 mm) 750N (Stromtec OÜ, töö nr 25-15)
0.300.30 0.30 0.30
hoiatuslint min 0.30
min 0.30
≥0.30
0.600.60
≥0.30
Purustatud kruus fr. 0.063 ...32 h= 10 cm Paekillustikust alus fr.32/63, kiilutud E≥170 MPa h= 25 cm Dreenkiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, kt=0,98
h= 20 cm
Tee mulle keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, kt=0,98
h= 25 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥65 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥65 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥65 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
M 1:50 1.40
0. 70
projekteeritud kaabelliin kaablikaitsetorus (PVC Ø160 või Ø110 mm) 450N (Stromtec OÜ, töö nr 25-15)
hoiatuslint
≥0.30
0.600.60
≥0.30
Kasvupinnas ja muru külv h= 10 cm Kaeviku tagasitäide välja kaevatud materjaliga, kt=0,92 h= 40 cm
Esmane tagasitäide keskteraline liiv/looduslik kruus või olemasolevpinnas, millest eemaldatud mitte sobiv materjal fr. 0.063 ...63, E≥60 MPa
h= 20 cm
Kaitsetoru sängituskiht keskteraline liiv/looduslik kruus fr. 0.063 ...63, E≥60 MPa
h= 5 cm
Tihendatud kaeviku küna põhi E≥60 MPa (tihendamise mitte saavutamisel kiiluda paekillustikuga 4/16, mis asendab kaitsetoru sängituskihti)
≥0.10≥0.10
Harri Laks; tel 53 835 935
Elektrilevi OÜ 25-15
Asendiplaan
09.07.2025
Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond. IP7497. Tööprojekt.
Jaanus Kaldoja
Töö nimetus:
Tellija:
Joonise nimetus:
Aadress: Päevalille 2-2, Ülenurme, Tartumaa; 61714
MTR: TEL002388 Reg. nr: 12688881 Telefon: +372 553 4119 E-mail: [email protected] Projekteerija: Kontrollis:
Kuupäev: Töö nr: Joonise nr: 10 Mõõtkava: M1:500/A1
OLEMASOLEVATE PUUDE EHITUSAEGNE KAITSE
prussid
pehmenduskiht autokummidest
traat
TÜVEKAITSEJUUREKAITSE
prussid kergkruus või killustik filterkangas
ol.olev maapind
kaevik
Üldmärkused: 1. Projekt on teostatud digitaliseeritud alusplaanile vastavalt Elektrilevi OÜ poolt väljastatud projekteerimisülesandele nr IP7497. 2. Alusplaanina on kasutatud Kirjanurk OÜ töö nr 13724G "Geodeetiline alusplaan" 17.06.2025. Kõrgused on EH2000 süsteemis, koordinaadid L-EST97 süsteemis. 3. Tehnovõrkude kaitsetsoonides kaevatakse käsitsi. Tööde teostamisel tuleb lähtuda liinirajatiste
kaitsevööndis tegutsemise eeskirjast. 4. Täitematerjal ei tohi sisaldada suuri kive (≥15 cm), kõrvalisi esemeid, turvast, pehmet savi, puidu-
või raadamisjäätmeid, jääd, lund ja külmunud pinnast (pinnasekamakaid), muid kahjustavaid ained ning jäätmeid. Talvetingimustes kasutada tagasitäitena ainult sulasid ja kergesti tihendatavaid materjale.
5. Katete taastamisel lähtuda töö aegsest olukorrast. Kui ehitustööde käigus selgub, et on kasutatud teistsugust konstruktsiooni, taastada katted vastavalt olemasolevale konstruktsioonile, et ei tekiks konstruktsioonilisi erinevusi. Olemasolevate puude juurestiku kaitsealal katendi taastamisel kasutada maksimaalselt olemasolevaid katendi aluskihte ja vältida kaevet puule lähemal olemasoleva katendi piirist. 6. Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas käsitsi või kinnisel viisel sügavamal kui 1m. 7. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava lõikevahendiga. 8. Kaabel paigaldada kogu trassi ulatuses minimaalselt 0,7m sügavusele ning paralleelkulgemisel ja ristumisel sõiduteega minimaalselt 1,0m sügavusele, kui asendiplaanil pole kirjas teisiti. 9. Pärast töid taastada endine olukord ning korrastada ehitusjäljed. 10. Kaablite ja elektriseadmete paigaldamisel järgida kehtivates normdokumentides sätestatut ja valmistajatehase nõudeid. Normdokumentide nimekirja vt. seletuskirjast.
m in
. 2 5
cm ra ja
tis e
te ge
lik pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ka ab
li pa
ig al
du ss
üg av
us
ra ja
tis e
te ge
lik p
ai ga
ld us
sü ga
vu s
va st
av al
t l ah
tik ae
va m
ise le
m in
. 2 5
cm
va st
av al
t l ah
tik ae
va m
ise le
RISTUMINE ALLPOOL (Rakendada juhtudel kui ei ole võimalik tagada pealt-poolt ristumise gabariite või trassivaldaja nõusolekul) RISTUMINE PEALTPOOLT
olemasolev maa-alune kommunikatsioon
projekteeritud trass
RISTUMINE TEISTE MAA-ALUSTE KOMMUNIKATSIOONIDEGA (VESI, KANALISATSIOON, KAUGKÜTE, SIDE...)
STROMTEC OÜ TÖÖ NR 25-15 TINGMÄRGID Proj. keskpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W2
Proj. madalpinge maakaabel kaitsetorus (esimene nr on kaablite arv kaevikus)1W1
Proj. maakaabelliini jätkumuhv
Proj. kinnise läbindamise meetod
Proj. kinnise läbindamise meetodi lähtekaevik
Proj. haljastuse taastamine (kaevetööde ala)
Proj. võsa raaadamine (kaevetööde ulatuses) Demonteeritav keskpinge õhuliin koos mastide ja toeelementidegaX
Proj. komplektalajaam
Ol. olev madalpinge maakaabel
Ol. olev keskpinge maakaabel
Katastriüksuse piir
Ol. olev madalpinge õhuliin
X Demonteeritav madalpinge õhuliin
Proj. kruuskatendi taastamine (kaevetööde ala)
X Tööst välja viidav keskpinge maakaabelliin
Ol. olev keskpinge õhuliin
From: "Harri Laks" <[email protected]> Sent: 7/10/2025 3:37:33 PM To: "RMK" <[email protected]> Cc:
Subject: 25-15 IP7497 Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond
You don't often get email from [email protected]. Learn why this is important
Tere! Stromtec OÜ projekteerib Elektrilevi OÜ tellimisel projekti ,,IP7497 Võsu-Vergi keskpinge õhuliini rekonstrueerimine I etapp Altja, Mustoja ja Haili küla, Haljala vald, Lääne-Viru maakond’’. Elektrilevi OÜ poolt väljastatud lähteülesanne näeb ette:
1. Jaanirahva (88703:001:0005) kinnistul asuva keskpinge õhuliini masti M150H6 demonteerimist koos lahk- ja mastivõimsuslülitiga.
2. Jaanirahva (88703:001:005) kinnistul asuvast mastist M150H76 kuni Sagadi metskond 296 (88701:001:0644) kinnistul asuva mastini M150H7 olemasoleva keskpinge maakaabelliini tööst välja viimist.
3. Sagadi metskond 296 (88701:001:0644) kinnistul asuvast mastist M150H7 kuni Uustalu (88703:002:2060) kinnistul asuva alajaamani AJ Mustoja olemasoleva keskpinge õhuliini demonteerimist koos mastide ja toeelementidega.
4. Uustalu (88703:002:2060) kinnistul asuva alajaama AJ Mustoja demonteerimist ning selle asendamist uue komplektalajaamaga AJ17045.
5. Uustalu (88703:002:2060) kinnistul uuest komplektalajaamast AJ17045 uute madalpinge maakaabelliinide rajamist kuni madalpinge õhuliini mastideni M1, taastamaks klientide ühendused.
6. Uustalu (88703:002:2060) kinnistul keskpinge õhuliini masti M150H27 demonteerimist koos lahklülitiga, masti tuleva keskpinge maakaabelliini ühendamist uude alajaama AJ17045.
7. Sagadi metskond 44 (88703:002:1710) kinnistul asuvast alajaamast AJ Mustoja II uue keskpinge maakaabelliini rajamist kuni Kukeseene (19101:001:0626) kinnistul asuva alajaamani AJ Metsakalju.
Saadan Teile üle vaatamiseks ning kooskõlastamiseks elektripaigaldise projekti. Lugupidamisega STROMTEC OÜ Projekteerija Harri Laks Mob +372 53 835 935 E-post [email protected]