Dokumendiregister | Rahandusministeerium |
Viit | 12.2-10/23-195/470-1 |
Registreeritud | 19.12.2023 |
Sünkroonitud | 25.03.2024 |
Liik | Sissetulev kiri |
Funktsioon | 12.2 RIIGIHANGETEALANE TEGEVUS (RRO, VAKO) |
Sari | 12.2-10 Riigihangete vaidlustusmenetluse toimikud |
Toimik | 12.2-10/23-195 |
Juurdepääsupiirang | Avalik |
Juurdepääsupiirang | |
Adressaat | OÜ Gamma Solutions |
Saabumis/saatmisviis | OÜ Gamma Solutions |
Vastutaja | Ulvi Reimets (Rahandusministeerium, Riigihangete vaidlustuskomisjon) |
Originaal | Ava uues aknas |
Riigihangete vaidlustuskomisjon
E-post: [email protected]
Asukoht: Tartu mnt 85, Tallinn, 10115
VAIE
Nimi, esindaja: OÜ Gamma Solutions, Kaur Kirjanen
Registrikood: 10677979
Aadress: Aardla tn 144-28, 50415 Tartu linn, Tartu maakond
Telefon: +372 5540983
E-post: [email protected]
OÜ Gamma Solutions vaidlustab sihtasutus Tartu Ülikooli Kliinikum hanke “ Kirurgilise sae ja trelli
komplektide ostmine„ viitenumber: 271393 otsuse pakkumine tagasi lükata ja ühe pakkuja
pakkumuse vastavaks tunnistamise.
Konkurendi pakkumuse vastavaks tunnistamine
OÜ Gamma Solutions vaidlustab pakkuja Osaühing B.Braun Medical pakkumuse vastavaks
tunnistamise, sest nende pakutavad akud ei vasta teadaolevalt hankija poolt kehtestatud tehnilistele
miinimumnõuetele. Tehniliste miinimumnõuete tabelis punktis 1.3.4. on küsitud „üks aseptiline
liitiumioon aku iga komplektis sisalduva käepideme kohta“. OÜ Gamma Solutions teadaolevalt pakub
pakkuja Osaühing B.Braun Medical ainult nikkel-metallhüdriidakud (NiMH) akusid, mis ei ole
samaväärsed liitiumioon akuga (Li-ion).
Riigihangete registris 26.10.2023 13:42 on esitatud küsimus: Kui pakutavate akude mahutavus vastab
tehnilise kirjelduse tingimustele, kas võib pakkuda liitiumioontehnoloogiast erineval tehnoloogial
põhinevat akut? Hankija vastas 1.11.2023 16:41 „Võib pakkuda muid variante, eriti kui need võiksid
mingites tingimustes olla hankijale paremad. Liitiumtehnoloogiast erineval tehnoloogial põhinevate
akude puhul palume esitada täpsemad spetsifikatsioonid ning kindlasti selgitused ja nende akude
eelised võrreldus küsitutega.“
OÜ Gamma Solutions leiab, et pakkumises 460246 (OÜ B.Braun Medical) eeldatavalt pakutud nikkel
metallhüdriidakud on võrreldes liitiumioon akudega vananenud tehnoloogia ning neid ei saa kuidagi
hankijale paremaks lugeda.
Põhjendused, miks NiMH akud ei ole paremad, kui Li-ion akud:
• NiMh akud ei säilita väljundvõimusust kogu tööprotsessi jooksul ehk aku tühjenedes kaob järk
järgult ka käepideme võimsus. Li-ion akud vastupidiselt säilitavad oma väljundvõimususe kuni lõplikult
tühjaks saamiseni.
• NiMH akudel on kiire isetühjenemine võrreldes Li-ion akudega.
• NiMH akudel on nn „mäluefekt“. NiMH akusid soovitatakse kord 3 kuu jooksul täiesti tühjaks
töötada mäluefekti vältimiseks.
• oluliselt väiksem energiatihedus - NiMH akud on sarnase võimuses juures suuremad ja
raskemad.
• NiMH akude eluiga sõltub korrektsest hooldusest ja hoiustamisest ning on väga tundlikud
madalate ja kõrgete temperatuuride suhtes.
Alternatiivsete aku võimaluste küsimusele vastati 1.11.2023, peale mida on hankija muutnud ka
tehnilise kirjelduse II versioonis akude kohta käivat punkti (algselt 1.3.3 ja hiljem 1.3.4) siis on selge,
et hankija soovib kindlasti hankida just liitiumioon akusid. Li-ion akusid soositakse tänu nende
väikesele kaalule ja kõrgete temperatuuride taluvusele, „mäluefekti“ puudumisele ja vähesele
hooldusvajadusele. Lisaks kõigele ei ole Li-Ion akud keskkonnale ohtlikud pärast nende kasutusaja
lõppu.
Pakkumise tagasilükkamine
Pakkuja sai 7.12.2023 hanke otsuse, kus põhjendatakse pakkumise tagasi lükkamist järgmiselt:
„Hankija sätestas hanke alusdokumen des järgmised vastavus ngimused:
5.9. Pakkujal tuleb esitada tehnilisele kirjeldusele vastav pakkumus vastavalt HD Lisale 1 (tabel 1 ja
tabel 2). HD Lisa 1 (tabel 1) punkt 3.4.8: AO trellipadrun luukanali freesidele (≤600 min-1, ≤9,5 Nm).
Pakkumuses esitatud trellipadruni parameetrid on 300min-1 – 20Nm.
Pakkumuse tagasilükkamise põhjuseks oli pakkumuse mi evastavus punk s 3.4.8 esitatud
ngimustele.“
OÜ Gamma Solu ons leiab, et trellpadruni parameetrite osas peaks lugema pakutud trellpadruni
samaväärseks ja isegi paremaks, kui vastavus ngimustes soovitud trellpadrunit.
OÜ Gamma Solutionsi poolt pakutav AO trellipadrun töötab kahes režiimis, mida saab käepidemelt
valida – “D” – drilling režiimis töötab otsik koodiga 15490 (kiirus / pöördemoment) 1350min-1 – 5Nm
ja „R“ –reaming režiimis töötab sama otsik 300min-1 – 20Nm. Mõlemal juhul saab kiirust ja jõudu
reguleerida käepidemel oleva nupu abil. See informatsioon on hankijale üheselt mõistetav, kuna
hankija küsimuse (28.11.2023 13:19) vastuses (29.11.2023 17:15) seda ka teiste sarnaste otsikute
kohta kinnitati. Seega pakkuja pakkumus vastab hanke tingimustele ja isegi ületab neid (saab valida
erinevaid režiime).
Mis puutub sellise unikaalse trellipadruni vajadusse, siis seda on pakkujal raske mõista. OÜ Gamma
Solutions on seda ka hanke käigus korduvalt küsinud. Antud tüübi (AO frees) padrunit kasutatakse
kanalisisese freesimise korral (ettepuuritav nael, kui reieluu kanal on endoproteesimise jaoks liiga
kitsas). Eesti haiglates kasutatavad AO painduvad kanalisisesed freesid (mida eelkirjeldatud
freesimise korral) kasutatakse on toodetud DePuySyntes kaubamärgi alt (Johnson&Johnson). Antud
freeside kasutusjuhendis “SynReam” (lisa 5) ei ole toodud ühtegi konkreetset juhist kiiruse ja
jõudluse osas.
Samuti ei ole kanalisisest freesimist kasutatavate naelte juhendites piiranguid freesi
pöördemomendile (lisatud pakkumise võitnud Zimmer Biometi Natural Nail kasutusjuhendid (3
tükki Lisad 6-8). Pigem on olnud juttu freesimise kiirusest, mille tõustes tõuseb ka kanalisisene
temperatuur ja mis omakorda võib avaldada negatiivset efekti kanalisisesele verevarustusele. Kui
vaadata erialast kirjandust, siis on kanalisisese freesimise vead kirjeldatud järgnevas tabelis, kust
puuduvad vihjed freesimise pöördemomendi osas, küll aga on juttu kanalisisese tempartuuri tõusu
negatiivsest efektist.
Table 1: Errors in reaming for intramedullary nails and associated consequence(s) of errors.
Kathryn C. Helmig, MD; Samer Kakish, MD; Thomas A. DeCoster, MD: Reaming Errors in
Intramedullary Nailing. Western Journal of Orthopaedics 2022; 11:24-28
Reaming Errors Consequence(s) of Error Over-Reaming Decreased interference fit
Thermal injury Malunion, delayed union, or nonunion
Under-Reaming Difficulty in advancing or removing nail Nail incarceration
Distraction at fracture site Malunion, delayed union, or nonunion
Reamer Selection – Dull reamer
– Narrow flutes – Non-cannulated reamer
Increased intramedullary pressure Fat embolism
Risk of reamer incarceration
Reamer Selection – Non-cannulated reamer
Inability to use ball-tipped guidewire Increased operative time
Eccentric reaming Malunion
Incarcerated Reamers – Increasing reamer size too quickly – Running reamer counter-clockwise
Need for corticotomy to remove reamer Unplanned removal of ball-tipped
guidewire Increased operative time
Reaming Technique – Reamer entry point and path
Malreduction Malunion
Eccentric reaming
Reaming Technique – Tourniquet use during reaming
Thermal injury to cortical bone and potentially skin/soft tissue Delayed union or nonunion
Reaming Technique – Failure to use a ball-tipped guidewire
– Failure to use an obturator
Eccentric reaming Malunion
Fracture comminution Unplanned removal of ball-tipped
guidewire Increased operative time
Reaming Technique – Failure to remove reaming debris
Heterotopic ossification
Kanalisisese freesimise kohta antakse ülevaade ka kirjanduse ülevaadetes ja metanalüüsides:
A-Bing Li, MD, Wei-Jiang Zhang, MD, Wei-Jun Guo, MD, Xin-Hua Wang, MD, Hai-Ming Jin, MD, You-Ming Zhao, MD: Reamed versus unreamed intramedullary nailing for the treatment of femoral fractures - A meta-analysis of prospective randomized controlled trials. Medicine 2016; 95(29): e4248.
Bhandari M., Guyatt G.H., Tong D., Adili A. & Shaughnessy S.G., Reamed versus non-reamed intramedullary nailing of lower extremity long bone fractures: a systematic overview and meta-analysis. J. Orthop. Trauma 2000; 14, 2-9
Nendes artiklites ei mainita kordagi kasutatavate freeside pöördemomente. Need on põhjused, miks
enamustel käepideme tootjatel puudub selline vahepealne kiire ja piiratud võimsusega frees nagu
hankija soovis.
Riigivarudesse tooted, mida varem pole vaja olnud
Kui pakkumine 460246 ei kvalifitseeru hankele, siis jääb ainult üks pakkumus, mis vastab kõikidele
tingimustele. Sellele faktile sai korduvalt viidatud hankemenetluse jooksul, et hanke tingimused on nii
ülesehitatud, et ainult üks pakkuja saab teha eduka pakkumuse. RHS § 88 lg 7 kohaselt peab tehniline
kirjeldus tagama kõigile ettevõtjatele võrdsed tingimused pakkumuse esitamiseks ega tohi tekitada
objektiivselt põhjendamatuid takistusi riigihangete avamisel konkurentsile. Seega RHS § 88 lg 7
sõnastusest nähtub, et hankija võib põhimõtteliselt tekitada ka tehnilise kirjelduse koostamisel
takistusi riigihangete avamisel konkurentsile, kuid need takistused peavad olema objektiivselt
põhjendatud. Pakkuja leiab, et ei ole ühtegi adekvaatset põhjendust, miks peaks selliste
parameetritega otsikuid üldse riigivarudesse hankima.
Riigihanke registris 27.10.2023 12:15 esitatud küsimusele vastas hankija 01.11.2023 16:26 “Kõikides
haiglates, kes teostavad ortopeedilisi operatsioone, on üldjuhul samad nõudmised, sest ortopeedias
puuduvad piirkondlikud erisused. Lisaks toimub antud hange riigivaru loomise eesmärgil, mille puhul
eeldatakse nende kasutamist kriisiolukordades täiendava instrumentaariumina eelkõige Põhja- ja Ida
Eesti piirkondades.“ OÜ Gamma Solutions on koostanud tabeli „Riigihanked 2017-2023“ (Lisa 3) kus
on näha riigihangete registris olevad ortopeediliste käepidemete hanked alates aastas 2017. Tabelis
on kollasega märgitud need hanked, kus on hangitud AO freesi padrunit (koos nõutavate
parameetritega – lahtrid „freesi kiirus“, „intramedullaane freesi kiirus“ ja „freesi pöördemoment“).
Tabelise on lisatud ka hange 272730, mis veel käib, kus sama hankija (SA Tartu Ülikooli Kliinikum)
hangib endale sarnase töö jaoks 5 komplekti käepidemeid (märgitud rohelisega). Ainuke erand on
märgitud punasega, kus hankija on teinud sarnaselt suunatud hanke ühele pakkujale (käepideme kaal,
puuri kiirus, freesi kiirus, intramedullaarse freesi kiirus ja 6 kohaline laadija, laadimisaeg jne.), osales
üks pakkuja ja võitis üks pakkuja, kelle toote brošüür on riigihanke keskkonnas üleval küsimuse 789921
27.10.2023 12:21 all.
Riigihangete vaidlustuskomisjon (VaKo) on vaidlustusasjas nr 88-22/250810 (p-s 7) põhjalikult
selgitanud, sh Riigikohtu lahenditele tuginedes, RHS § 88 lg 7 regulatsiooni sisu:
„RHS § 88 lg 7 kohaselt peab tehniline kirjeldus tagama kõigile ettevõtjatele võrdsed tingimused
pakkumuse esitamiseks ega tohi tekitada objektiivselt põhjendamatuid takistusi riigihangete avamisel
konkurentsile. Seega RHS § 88 lg 7 sõnastusest nähtub, et hankija võib põhimõtteliselt tekitada ka
tehnilise kirjelduse koostamisel takistusi riigihangete avamisel konkurentsile, kuid need takistused
peavad olema objektiivselt põhjendatud, mida selles hankes ei ole tehtud.
Taotleme seda vaiet esitades seda, et OÜ Gamma Solutions pakkumus tunnistataks tingimustele
vastavaks ja ettevõte pakkumust ei lükataks tagasi ning kontrollitaks ühe pakkuja pakkumuse
vastavaks tunnistamist.
Kinnitan, et vaieldavas asjas ei ole vaide esitamise hetkel jõustunud kohtuotsust ega toimu
kohtumenetlust.
Vaidlustaja soovib asja arutamist kirjalikus menetluses. Olen nõus, et vastus vaidele saadetakse mulle
elektrooniliselt e-posti aadressil [email protected].
Vaide esitamise kuupäev: 18.12.2023
(digitaalselt allkirjastatud)
Kaur Kirjanen
OÜ Gamma Solutions juhatuse liige
Lisan vaidele järgmised dokumendid: Lisa 1 – otsus.pdf Lisa 2 – tagasilükkamine.pdf Lisa 3 – Riigihanked 2017-2023.pdf Lisa 4 – riigilõivu maksmise kinnitus.pdf Lisa 5 – SynReam.pdf Lisa 6 – Zimmer Natural Nail – cephalomedullary.pdf Lisa 7 - Zimmer Natural Nail – femoral.pdf Lisa 8 - Zimmer Natural Nail – tibia.pdf
Nimi | K.p. | Δ | Viit | Tüüp | Org | Osapooled |
---|---|---|---|---|---|---|
Riigilõivu tagastamise otsus | 28.02.2024 | 27 | 12.2-10/23-195/470-6 | Väljaminev kiri | ram | OÜ Gamma Solutions |
Riigilõivu tagastamise taotlus | 30.01.2024 | 56 | 12.2-10/23-195/470-5 | Sissetulev kiri | ram | OÜ Gamma Solutions |
Otsus | 27.12.2023 | 90 | 12.2-10/23-195/470-4 | Väljaminev kiri | ram | OÜ Gamma Solutions, sihtasutus Tartu Ülikooli Kliinikum |
Hankija teade | 22.12.2023 | 95 | 12.2-10/23-195/470-3 | Sissetulev kiri | ram | sihtasutus Tartu Ülikooli Kliinikum |
Vaidlustuse esitamise teade | 19.12.2023 | 98 | 12.2-10/23-195/470-2 | Väljaminev kiri | ram | OÜ Gamma Solutions, sihtasutus Tartu Ülikooli Kliinikum |